FRV Series
FRV Series

FRV Series

Application
Application

Line Voltage Power Supply, Transformer and Appliances

Information

Maximum Operation Current
0.05A~2.00A
Maximum Operating Voltage
240VAC/DC
Maximum Interrupt Voltage
265VAC/DC

Features

Low hold current, Solid state, Radial leaded product ideal for up to 265VAC/DC

Temperature Range
Temperature Range

FRV005-240F~FRV055-240F -40℃ to 85℃
FRV075-240F~FRV200-240F -20℃ to 85℃

Spec Download

Part
Number
Hold
Current
Trip
Current
Rated
Voltage
Max
Current
Max. Int.
Voltage
Typ.
Power
Max.
Time to Trip
Resistance
IH, A IT, A VMAX, VAC/DC IMAX, A VMAX, V AC/DC Pd, W @ 5 x IH, s RMIN R1MAX
FRV005-240F 0.05 0.12 240 1 265 0.7 15 18.5 65
FRV008-240F 0.08 0.19 240 1.2 265 0.8 15 7.4 26
FRV012-240F 0.12 0.3 240 1.2 265 1 15 3 12
FRV016-240F 0.16 0.37 240 2 265 1.4 15 2.5 7.8
FRV025-240F 0.25 0.56 240 3.5 265 1.5 18.5 1.3 3.8
FRV033-240F 0.33 0.74 240 4.5 265 1.7 21 0.83 2.6
FRV040-240F 0.4 0.9 240 5.5 265 2 24 0.6 1.9
FRV055-240F 0.55 1.25 240 7 265 3.4 26 0.45 1.45
FRV075-240F 0.75 1.5 240 7.5 265 2.6 18 0.32 0.84
FRV100-240F 1 2 240 10 265 2.9 21 0.22 0.58
FRV125-240F 1.25 2.5 240 12.5 265 3.3 23 0.17 0.44
FRV150-240F 1.5 3 240 15 265 3.7 23 0.12 0.32
FRV200-240F 2 4 240 20 265 4.5 28 0.09 0.22

This website uses Cookie to offer you the best user experience and analyze data. By using our website, you agree to the use of cookies in accordance with this Cookie Policy. For more details, Please refer to our Privacy Policy for further details.