FRX Series PPTC自恢复式保险丝
|
Part Number |
Hold Current |
Trip Current |
Max. Time to Trip |
Max Current |
Rated Voltage |
Typ. Power |
Resistance | |
|---|---|---|---|---|---|---|---|---|
| IH, A | IT, A | @ 5 x IH, s | IMAX, A | V Max, V DC | Pd, W | Rmin | R1max | |
| FRX005-60F | 0.05 | 0.1 | 5 | 40 | 60 | 0.26 | 7.3 | 20 |
| FRX010-60F | 0.1 | 0.2 | 4 | 40 | 60 | 0.38 | 2.5 | 7.5 |
| FRX017-60F | 0.17 | 0.34 | 3 | 40 | 60 | 0.48 | 2 | 8 |
| FRX020-60F | 0.2 | 0.4 | 2.2 | 40 | 60 | 0.41 | 1.83 | 4.4 |
| FRX025-60F | 0.25 | 0.5 | 2.5 | 40 | 60 | 0.45 | 1.25 | 3 |
| FRX030-60F | 0.3 | 0.6 | 3 | 40 | 60 | 0.49 | 0.88 | 2.1 |
| FRX040-60F | 0.4 | 0.8 | 3.8 | 40 | 60 | 0.56 | 0.55 | 1.29 |
| FRX050-60F | 0.5 | 1 | 4 | 40 | 60 | 0.77 | 0.5 | 1.17 |
| FRX065-60F | 0.65 | 1.3 | 5.3 | 40 | 60 | 0.88 | 0.31 | 0.72 |
| FRX075-60F | 0.75 | 1.5 | 6.3 | 40 | 60 | 0.92 | 0.25 | 0.6 |
| FRX090-60F | 0.9 | 1.8 | 7.2 | 40 | 60 | 0.99 | 0.2 | 0.47 |
| FRX110-60F | 1.1 | 2.2 | 8.2 | 40 | 60 | 1.5 | 0.15 | 0.38 |
| FRX135-60F | 1.35 | 2.27 | 9.6 | 40 | 60 | 1.7 | 0.12 | 0.3 |
| FRX160-60F | 1.6 | 3.2 | 11.4 | 40 | 60 | 1.9 | 0.09 | 0.22 |
| FRX185-60F | 1.85 | 3.7 | 12.6 | 40 | 60 | 2.1 | 0.08 | 0.19 |
| FRX250-60F | 2.5 | 5 | 15.6 | 40 | 60 | 2.5 | 0.05 | 0.13 |
| FRX300-60F | 3 | 6 | 19.8 | 40 | 60 | 2.8 | 0.04 | 0.10 |
| FRX375-60F | 3.75 | 7.5 | 24 | 40 | 60 | 3.2 | 0.03 | 0.08 |